1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 65
Alarm No.: 67
Name: Encoder normal communication error 1 (safety observation function)
Alarm content
An error has occurred in the communication between an encoder and servo amplifier.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
67.1 Encoder
normal
communication -
Receive data
error 1 (safety
observation
function)
(1) An encoder cable is
malfunctioning.
Check if the encoder
cable is disconnected
or shorted.
It has a failure.
Repair or replace
the cable.
[A]
[B]
[GF]
It has no failure.
Check (2).
(2) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (3).
(3) An encoder is
malfunctioning.
Replace the servo
motor, and then check
the repeatability.
It is not repeatable.
Replace the servo
motor.
It is repeatable.
Check (4).
(4) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
67.2 Encoder
normal
communication -
Receive data
error 2 (safety
observation
function)
Check it with the check method for [AL. 67.1].
67.3 Encoder
normal
communication -
Receive data
error 3 (safety
observation
function)
67.4 Encoder
normal
communication -
Receive data
error 4 (safety
observation
function)
67.7 Encoder
normal
communication -
Transmission
data error 1
(safety
observation
function)
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...