1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 50
Alarm No.: 39
Name: Program error
Alarm content
A program used for the program operation is incorrect.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
39.1 Program error
(1) A checksum of the
program did not match
at power-on. (The
program has an error.)
Check if an error
occurred (such as
entered noise, power-
off) at program write.
It has a failure.
Rewrite the
program.
[A]
It has no failure.
Check (2).
(2) A program has
changed due to a servo
amplifier malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
39.2 Instruction
argument
external error
(1) A program has never
been written since
program initialization.
Check if a program
was written.
It was not executed. Write the program.
It was executed.
Check (2).
(2) A command argument is
using a value out of
specifications.
Check if the command
description has a
failure.
It has a failure.
Correct the
command
description.
It has no failure.
Check (3).
(3) A program has
changed due to a servo
amplifier malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
39.3 Register
No.
error
(1) A specified number of
the general purpose
register used for a
command is a value
out of specifications.
Check if the command
description has a
failure.
It has a failure.
Correct the
command
description.
It has no failure.
Check (2).
(2) A program has
changed due to a servo
amplifier malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
39.4 Non-
correspondence
instruction error
(1) A used command is not
correspondent to the
program.
Check if the command
description has a
failure.
It has a failure.
Correct the
command
description.
It has no failure.
Check (2).
(2) A program has
changed due to a servo
amplifier malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
Alarm No.: 3A
Name: Inrush current suppression circuit error
Alarm content
The inrush current suppression circuit error was detected.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
3A.1 Inrush
current
suppression
circuit error
(1) Inrush
current
suppressor circuit is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
[A]
[B]
[WB]
[RJ010]
[GF]
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...