1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 111
Alarm No.: F4
Name: Positioning warning
Alarm content
Target position or acceleration time constant/deceleration time constant was set out of setting range.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F4.4 Target
position
setting
range error
warning
(1) A target position was
set out of setting range.
Check the setting
value of the target
position.
It is out of setting
range.
Set the target
position correctly,
and cancel the
warning (turn on
C_ORST).
[Others]
F4.6 Acceleration
time constant
setting range
error warning
(1) An acceleration time
constant was set out of
setting range.
Check the setting
value ([Pr. PT49]) of
the acceleration time
constant.
It is out of setting
range.
Set the
acceleration time
constant correctly,
and cancel the
warning (turn on
ORST).
[GF]
F4.7 Deceleration
time constant
setting range
error warning
(1) A deceleration time
constant was set out of
setting range.
Check the setting
value ([Pr. PT50]) of
the deceleration time
constant.
It is out of setting
range.
Set the
deceleration time
constant correctly,
and cancel the
warning (turn on
ORST).
F4.9 Home
position
return type
error warning
(1) A home position return
type was set out of
setting range.
Check the setting
value ([Pr. PT45]) of
the home position
return type.
It is not corresponding
to a value for the
home position return
type.
Set the home
position return type
correctly, and
cancel the warning
(turn on ORST).
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...