1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 128
Description
Possible cause
Check result
Action
Target
Modbus-RTU communication
is not established.
The servo amplifier is not set
to Modbus-RTU
communication protocol.
Check if "communication
protocol selection" in [Pr.
PC71] is correctly set.
Select Modbus-RTU protocol. [A]
The communication setting is
not set correctly.
Check if [Pr. PC70 Modbus-
RTU communication station
number setting] is set
correctly.
Check [Pr. PC70 Modbus-
RTU communication station
number setting] and the
station No. specified in a
Query message from the
controller if they are matched
together.
Check if "Modbus-RTU
communication baud rate
selection" in [Pr. PC71] is set
correctly.
Check "Modbus-RTU
communication baud rate
selection" and the
communication baud rate
setting of the controller if
they are matched together.
Check if "Modbus-RTU
communication parity
selection" in [Pr. PF45] is set
correctly.
Check "Modbus-RTU
communication parity
selection" and the parity
setting of the controller if
they are matched together.
The servo amplifier is not
compatible with Modbus-RTU
communication.
For MR-J4-_A_-RJ 100 W or
more servo amplifier, check
that the servo amplifier was
manufactured in January
2015 or later.
Check if MR-J4-_A_ servo
amplifier or MR-J4-03A6(-RJ)
servo amplifier is being used.
For MR-J4-_A_-RJ 100 W or
more servo amplifier, use the
one manufactured in January
2015 or later.
(MR-J4-_A_ servo amplifier or
MR-J4-03A6(-RJ) servo
amplifier is not compatible
with Modbus-RTU
communication.)
A communication cable is
malfunctioning.
Check if the communication
cable has any failure such as
damage.
Replace the communication
cable.
RS-422 communication
(Mitsubishi general-purpose
AC servo protocol) is not
established.
The servo amplifier is not set
to RS-422 communication
protocol.
Check if "communication
protocol selection" in [Pr.
PC71] is correctly set.
Select RS-422/RS-485
communication (Mitsubishi
general-purpose AC servo
protocol).
[A]
The communication setting is
not set correctly.
Check if [Pr. PC20 Station
number setting] is set
correctly.
Check [Pr. PC20 Station
number setting] and the
station No. specified by the
controller if they are matched
together.
Check if "RS-422
communication baud rate
selection" in [Pr. PC21] is set
correctly.
Check "RS-422
communication baud rate
selection" and the
communication baud rate
setting of the controller if they
are matched together.
A communication cable is
malfunctioning.
Check if the communication
cable has any failure such as
damage.
Replace the communication
cable.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...