4. DRIVE RECORDER
4 - 3
Table 4.1 MR-J4-_B_(-RJ), MR-J4-_B_-RJ010, or MR-J4W_-_B
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Sampling
time [ms]
Measure-
ment time
[ms]
Standard
Analog Motor
speed
Torque Current
command
Droop
pulses
(1 pulse)
Speed
command
Bus
voltage
Effective
load ratio
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 10
Analog Motor
speed
Torque Current
command
Droop
pulses
(1 pulse)
Speed
command
Bus
voltage
Effective
load ratio
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 20
Analog Motor
speed
Torque ABS
counter
Within one-
revolution
position
Current
command
Encoder
error
counter 1
Encoder
error
counter 2
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 21
Analog Motor
speed
Torque ABS
counter
Within one-
revolution
position
Current
command
Encoder
error
counter 1
Encoder
error
counter 2
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 24
Analog Motor
speed
Torque Current
command
Within one-
revolution
position
Bus
voltage
U-phase
current
feedback
V-phase
current
feedback
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 30
Analog Motor
speed
Torque Current
command
Droop
pulses
(1 pulse)
Bus
voltage
Regene-
rative load
ratio
Effective
load ratio
56.8 14563
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 31
Analog Motor
speed
Torque Current
command
Command
pulse
frequency
Within one-
revolution
position
Speed
command
Bus
voltage
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 32
Analog Motor
speed
Torque Current
command
Bus
voltage
Effective
load ratio
U-phase
current
feedback
V-phase
current
feedback
0.444 113
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 33
Analog Motor
speed
Torque Current
command
Speed
command
Bus
voltage
Regene-
rative load
ratio
Effective
load ratio
3.5 910
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 35
Analog Motor
speed
Torque Current
command
Command
pulse
frequency
Droop
pulses
(1 pulse)
Speed
command
Bus
voltage
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 42
(Note)
Analog Motor
speed
Torque Motor-side/
load-side
position
deviation
(100
pulses)
Motor-side/
load-side
speed
deviation
Command
pulse
frequency
(speed
unit)
Droop
pulses
(100
pulses)
Load-side
droop
pulses
(100
pulses)
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 46
Analog Motor
speed
Torque Current
command
Internal
tempera-
ture of
encoder
Tempera-
ture of
motor
thermistor
Bus
voltage
Effective
load ratio
56.8 14563
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 50
Analog Motor
speed
Torque Current
command
Droop
pulses
(100
pulses)
Overload
alarm
margin
Bus
voltage
Effective
load ratio
56.8 14563
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 51
Analog Motor
speed
Torque Current
command
Droop
pulses
(100
pulses)
Overload
alarm
margin
Bus
voltage
Effective
load ratio
56.8 14563
Digital CSON EMG ALM2 INP MBR RD
STO IPF
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...