1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 92
1.5 Remedies for warnings
CAUTION
If [AL. E3 Absolute position counter warning] occurs, remove the cause of the
warning, and always make home position setting again. Otherwise, it may cause
an unexpected operation.
POINT
When any of the following alarms has occurred, do not cycle the power of the
servo amplifier repeatedly to restart. Doing so will cause a malfunction of the
servo amplifier and servo motor. If the power of the servo amplifier is switched
off/on during the alarms, allow more than 30 minutes for cooling before
resuming operation.
[[AL. 91 Servo amplifier overheat warning]
[AL. E0 Excessive regeneration warning]
[AL.E1 Overload warning 1]
[AL. E2 Servo motor overheat warning]
[AL.EC Overload warning 2]
Warnings (except [AL. F0 Tough drive warning]) are not recorded in the alarm
history.