1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 27
Alarm No.: 17
Name: Board error
Alarm content
A part in the servo amplifier is malfunctioning.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
17.6 Board error 5
(1) The setting value of the
control axis setting
switch (SW2) was not
read properly.
Disconnect the cables
except for the control
circuit power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
[B]
[WB]
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
17.7 Board error 7
Check it with the check method for [AL. 17.4].
17.8 Board error 6
(1) Inrush current
suppressor circuit is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
[B]
[WB]
17.9 Board error 8
(1) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
[GF]
It has no failure.
Check (2).
(2) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
Alarm No.: 19
Name: Memory error 3 (Flash-ROM)
Alarm content
A part (Flash-ROM) in the servo amplifier is failure.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
19.1 Flash-ROM
error 1
(1) The Flash-ROM is
malfunctioning.
Disconnect the cables
except for the control
circuit power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
[A]
[B]
[WB]
[RJ010]
[GF]
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
19.2 Flash-ROM
error 2
Check it with the check method for [AL. 19.1].
19.3 Flash-ROM
error 3
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...