3. TROUBLESHOOTING FOR MR-CR55K(4) RESISTANCE REGENERATION CONVERTER UNIT
3 - 2
3.3 Remedies for alarms
CAUTION
When any alarm has occurred, eliminate its cause, ensure safety, and deactivate
the alarm before restarting operation. Otherwise, it may cause injury.
POINT
When any of the following alarms has occurred, do not deactivate the alarm
repeatedly to restart. Otherwise, the resistance regeneration converter unit may
malfunction. Remove its cause and allow about 30 minutes for cooling before
resuming the operation.
[AL. 30 Regenerative error]
[AL. 45 Main circuit device overheat]
[AL. 50 Overload 1]
[AL. 51 Overload 2]
[AL. 37 Parameter error] is not recorded in the alarm history.
Remove the cause of the alarm in accordance with this section.