1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 86
Alarm No.: 86
Name: Network communication error
Alarm content
An error occurred in the network module.
An error occurred in the network communication.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
86.1 Network
communication
error 1
(1) The network module
was disconnected.
Check if the network
module is connected
correctly.
It is not connected
correctly.
Connect it correctly. [Other]
It is connected
correctly.
Check (2).
(2) A network cable was
disconnected.
Check if the network
cable is connected
correctly.
It is not connected.
Turn off the control
circuit power supply
of the servo
amplifier, and then
connect the network
cable correctly.
It is connected.
Check (3).
(3) The wiring of the
network cable was
incorrect.
Check if the wiring of
network cable is
correct.
The wiring is
incorrect.
Wire it correctly.
The wiring is
correct.
Check (4).
(4) A network cable was
disconnected.
Check if the network
cable is
malfunctioning.
It has a failure.
Replace the network
cable.
It has no failure.
Check (5).
(5) The network was
disconnected by a
wrong procedure.
Check if the network
was disconnected
according to the kind
of network.
It was not
performed.
Perform it.
It was performed.
Check (6).
(6) Data transmission from
the controller was
interrupted for a certain
period of time.
Check if data
transmission from the
controller is not
interrupted.
It is interrupted.
Review the
controller
communication
setting.
It is not interrupted. Check (7).
(7) The setting of the
controller is incorrect.
Check the controller
setting.
It is incorrect.
Review the settings.
It is correct.
Check (8).
(8) Something near the
device caused it.
Check the noise,
ambient temperature,
etc. Refer to section
11.14 for the noise
reduction techniques.
It has a failure.
Take
Countermeasures
against its cause.
It has no failure.
Check (9).
(9) The network module is
malfunctioning.
Replace the network
module, and then
check the
repeatability.
It is not repeatable.
Replace the network
module.
It is repeatable.
Check (10).
(10) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (11).
(11) The controller is
malfunctioning.
Replace the
controller, and then
check the
repeatability.
It is not repeatable.
Replace the
controller.
86.2 Network
communication
error 2
Check it with the check method for [AL. 86.1].
86.3 Network
communication
error 3
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...