4. DRIVE RECORDER
4 - 8
Table 4.4 Signal explanations
Signal
name
Description
Unit
Analog
Motor speed
The servo motor speed is displayed.
[r/min]
Torque
The servo motor torque is displayed with current value.
The value of torque being occurred is displayed in real time considering a rated torque as
100%.
[0.1%]
Current command
This indicates current command applying to the servo motor.
[0.1%]
Droop pulses (1 pulse) This indicates the number of droop pulses in the deviation counter per pulse.
[pulse]
Droop pulses
(100 pulses)
This indicates the number of droop pulses in the deviation counter per 100 pulses.
[100 pulses]
Speed command
This indicates speed command applying to the servo motor.
[r/min]
Bus voltage
This indicates bus voltage at the converter of the servo amplifier.
[V]
Effective load ratio
The continuous effective load torque is displayed. This indicates effective value for past
15 seconds.
[0.1%]
ABS counter
The travel distance from the home position is displayed as multi-revolution counter value
of the absolution position encoder in the absolution position detection system.
[rev]
Within
one-revolution
position
Position within one revolution is displayed in encoder pulses.
[16 pulses]
Encoder error counter
1
This indicates the number of cumulative errors during a communication with the encoder.
[times]
Encoder error counter
2
The same as encoder error counter 1.
[times]
U-phase
current
feedback
This indicates U-phase current value applying to the servo motor per internal unit.
V-phase
current
feedback
This indicates V-phase current value applying to the servo motor per internal unit.
Regenerative
load
ratio
The ratio of regenerative power to permissible regenerative power is displayed in %.
[0.1%]
Command
pulse
frequency
This indicates the command pulse frequency.
[1.125 kpps]
Command
pulse
frequency (speed unit)
This converts and indicates command pulse frequency per servo motor speed.
[r/min]
Motor-side/load-side
position deviation
(100 pulses)
This indicates a deviation between motor-side position and load-side position during fully
closed loop control.
The number of pulses displayed is in the load-side encoder pulse unit.
[100 pulses]
Motor-side/load-side
speed deviation
This indicates a deviation between motor speed and load-side speed during fully closed
loop control.
[r/min]
Load-side
droop
pulses (100 pulses)
Droop pulses of the deviation counter between a load-side position and a command are
displayed.
[100 pulses]
Internal
temperature
of encoder
Inside temperature of encoder detected by the encoder is displayed.
[
˚
C]
Temperature of motor
thermistor
The thermistor temperature is displayed for the rotary servo motor with thermistor, linear
servo motor with thermistor, and direct drive motor.
[
˚
C]
Overload alarm margin This indicates margins to the levels which trigger [AL. 50 Overload 1] and [AL. 51
Overload 2] in percent. When the value becomes 0%, the overload alarm will occur.
[0.1%]
Error excessive alarm
margin
This indicates a margin to the level which trigger the error excessive alarm in encoder
pulse unit. When the value becomes 0 pulse, the error excessive alarm will occur.
[pulse]
Load-side
encoder
information 1
The position in load-side encoder 1-revolution is displayed. This indicates a Z-phase
counter for the INC linear encoder. The value is counted up from 0 based on the home
position (reference mark). This indicates an absolute position for the ABS linear encoder.
It is displayed in load-side encoder pulse unit.
[pulse]
Load-side
encoder
information 2
Multi-revolution counter of the load-side encoder is displayed.
[pulse]
Load-side
encoder
error counter 1
This indicates the number of cumulative errors during a communication with the load-side
encoder.
[times]
Load-side
encoder
error counter 2
The same as load-side encoder error counter 1.
[times]
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...