4. DRIVE RECORDER
4 - 9
Signal
name
Description
Unit
Digital
CSON
This indicates status of the servo-on signal from the controller.
SON
This Indicates the SON status of the external input signal.
EMG
This indicates status of the emergency stop input.
EM2/EM1
This Indicates the EM2/EM1 status of the external input signal.
ALM2
This will turn on when an alarm is detected in the servo amplifier. This changes faster
than ALM of the external output signal.
INP
This indicates INP status of the external output signal.
MBR
This indicates MBR status of the external output signal.
RD
This indicates RD status of the external output signal.
STO
This Indicates the STO status of the external input signal.
IPF
This will turn on when the control circuit power becomes instantaneous power failure
status.