1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 29
Alarm No.: 1E
Name: Encoder initial communication error 2
Alarm content
An encoder is malfunctioning.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
1E.1 Encoder
malfunction
(1) An encoder is
malfunctioning.
Replace the servo
motor, and then
check the
repeatability.
It is not repeatable.
Replace the servo
motor.
[A]
[B]
[WB]
[RJ010]
[GF]
It is repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
1E.2 Load-side
encoder
malfunction
(1) A load-side encoder is
malfunctioning.
Replace the load-side
encoder, and then
check the
repeatability.
It is not repeatable.
Replace the load-
side encoder.
[A]
[B]
[WB]
[GF]
It is repeatable.
Check (2).
(2) Something near the
device caused it.
Check the noise,
ambient temperature,
vibration, etc.
It has a failure.
Take
countermeasures
against its cause.
Alarm No.: 1F
Name: Encoder initial communication error 3
Alarm content
The connected encoder is not compatible with the servo amplifier.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
1F.1 Incompatible
encoder
(1) A servo motor or linear
encoder, which is not
compatible with the
servo amplifier, was
connected.
Check the model the
servo motor/linear
encoder.
It is not compatible
with the servo
amplifier.
Replace it with a
compatible one.
[A]
[B]
[WB]
[RJ010]
[GF]
It is compatible with
the servo amplifier.
Check (2).
(2) The software version of
the servo amplifier does
not support the servo
motor or linear encoder.
Check if the software
version supports the
servo motor/linear
encoder.
It is not compatible. Replace the servo
amplifier to one
which software
version supports the
servo motor/linear
encoder.
It is compatible.
Check (3).
(3) An encoder is
malfunctioning.
Replace the servo
motor or linear
encoder, and then
check the
repeatability.
It is not repeatable.
Replace the servo
motor or linear
encoder.
It is repeatable.
Replace the servo
amplifier.
1F.2 Incompatible
load-side
encoder
(1) A load-side encoder,
which is not compatible
with the servo amplifier,
was connected.
Check the model of
the load-side
encoder.
It is not compatible
with the servo
amplifier.
Use a load-side
encoder which is
compatible with the
servo amplifier.
[A]
[B]
[WB]
[GF]
It is compatible with
the servo amplifier.
Check (2).
(2) The software version of
the servo amplifier
does not support the
load-side encoder.
Check if the software
version of the servo
amplifier supports the
load-side encoder.
It is not compatible. Replace the servo
amplifier to one
which software
version supports the
load-side encoder.
It is compatible.
Check (3).
(3) A load-side encoder is
malfunctioning.
Replace the load-side
encoder, and then
check the
repeatability.
It is not repeatable.
Replace the load-
side encoder.
It is repeatable.
Replace the servo
amplifier.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...