1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 112
Alarm No.: F5
Name: Simple cam function - Cam data miswriting warning
Alarm content
The cam data written by MR Configurator2 is not written to a Flash-ROM.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F5.1 Cam data -
Area writing
time-out
warning
(1) The Flash-ROM is
malfunctioning.
Disconnect the cables
except for the control
circuit power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
[A]
[GF]
F5.2 Cam data -
Miswriting
warning
(1) The cam data was not
written.
After the power is
cycled, perform
writing, and check the
repeatability again.
When the cam data is
initialized, perform
writing, and check the
repeatability again.
(Refer to section 7.2.9
[Pr. PT34] of "MR-J4-
_A_-RJ Servo
Amplifier Instruction
Manual (Positioning
Mode)", and section
3.2.4 [Pr. PT34] of
"MR-J4-_GF_(-RJ)
Servo Amplifier
Instruction Manual
(I/O Mode)".)
It is repeatable.
Replace the servo
amplifier.
F5.3 Cam
data
checksum error
(1) When the power is
switched on after the
cam data is written, a
checksum of the cam
data does not match.
(Error occurred in cam
data.)
Check if an error
occurred (such as
entered noise, power-
off) at cam data write.
It has a failure.
After writing the cam
data again, cycle
the power.
It has no failure.
Check (2).
(2) When the cam control
command is turned on
after the temporal
writing of cam data, a
checksum of the cam
data does not match.
(Error occurred in cam
data.)
Check if an error
occurred (such as
entered noise) at
temporal writing of
cam data.
It has a failure.
After performing the
temporal writing of
cam data again, turn
on the cam control
command.
It has no failure.
Check (3).
(3) The Flash-ROM is
malfunctioning.
Replace the servo
amplifier, and then
check the repeatability.
It is not repeatable.
Replace the servo
amplifier.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...