1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 110
Alarm No.: F0
Name: Tough drive warning
Alarm content
Tough drive function was activated.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F0.1 Instantaneous
power failure
tough drive
warning
(1) The voltage of the
control circuit power
supply has dropped.
Check it with the check method for [AL. 10.1].
[A]
[B]
[WB]
[RJ010]
[GF]
F0.3 Vibration
tough
drive warning
(1) The setting value of the
machine resonance
suppression filter was
changed due to a
machine resonance.
Check if it was
changed frequently.
It was changed
frequently.
Set the machine
resonance
suppression filter.
Check the machine
status if screws are
loose or the like.
Alarm No.: F2
Name: Drive recorder - Miswriting warning
Alarm content
A waveform measured by the drive recorder function was not recorded.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F2.1 Drive recorder -
Area writing
time-out
warning
(1) The Flash-ROM is
malfunctioning.
Disconnect the cables
except for the control
circuit power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
[A]
[B]
[WB]
[RJ010]
[GF]
F2.2 Drive recorder -
Data miswriting
warning
(1) Data were not written to
the drive recorder area.
Check if clearing alarm
history disables this
alarm with MR
Configurator2.
It is not canceled.
Replace the servo
amplifier.
Alarm No.: F3
Name: Oscillation detection warning
Alarm content
[AL. 54 Oscillation detection] can occur.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
F3.1 Oscillation
detection
warning
Check it with the check method for [AL. 54.1].
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...