4. DRIVE RECORDER
4 - 4
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Sampling
time [ms]
Measure-
ment time
[ms]
AL. 52
Analog Motor
speed
Torque Current
command
Droop
pulses
(100
pulses)
Speed
command
Bus
voltage
Error
excessive
alarm
margin
3.5 910
Digital CSON EMG ALM2 INP MBR RD
STO TLC
AL. 71
(Note)
Analog Motor
speed
Torque Load-side
encoder
information
2
Load-side
encoder
information
1
Current
command
Load-side
encoder
error
counter 1
Load-side
encoder
error
counter 2
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
AL. 72
(Note)
Analog Motor
speed
Torque Load-side
encoder
information
2
Load-side
encoder
information
1
Current
command
Load-side
encoder
error
counter 1
Load-side
encoder
error
counter 2
0.888 227
Digital CSON EMG ALM2 INP MBR RD
STO IPF
Note. MR-J4-_B_-RJ010 is not supported.