1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 104
Alarm No.: E0
Name: Excessive regeneration warning
Alarm content
There is a possibility that regenerative power may exceed permissible regenerative power of built-in
regenerative resistor or regenerative option.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
E0.1 Excessive
regeneration
warning
(1) The
regenerative
power exceeded 85%
of the permissible
regenerative power of
the built-in regenerative
resistor or regenerative
option.
Check the effective
load ratio.
It is 85% or more.
Reduce the
frequency of
positioning.
Increase the
deceleration time
constant.
Reduce the load.
Use a regenerative
option if it is not
being used.
[A]
[B]
[WB]
[RJ010]
[GF]
Alarm No.: E1
Name: Overload warning 1
Alarm content
[AL. 50 Overload 1] or [AL. 51 Overload 2] can occur.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
E1.1 Thermal
overload
warning 1
during operation
(1) The load was over 85%
to the alarm level of [AL.
50.1 Thermal overload
error 1 during
operation].
Check it with the check method for [AL. 50.1].
[A]
[B]
[WB]
[RJ010]
[GF]
E1.2 Thermal
overload
warning 2
during operation
(1) The load was over 85%
to the alarm level of [AL.
50.2 Thermal overload
error 2 during
operation].
Check it with the check method for [AL. 50.2].
E1.3 Thermal
overload
warning 3
during operation
(1) The load was over 85%
to the alarm level of [AL.
51.1 Thermal overload
error 3 during
operation].
Check it with the check method for [AL. 51.1].
E1.4 Thermal
overload
warning 4
during operation
(1) The load was over 85%
to the alarm level of [AL.
50.3 Thermal overload
error 4 during
operation].
Check it with the check method for [AL. 50.3].
E1.5 Thermal
overload error 1
during a stop
(1) The load was over 85%
to the alarm level of [AL.
50.4 Thermal overload
error 1 during a stop].
Check it with the check method for [AL. 50.4].
E1.6 Thermal
overload error 2
during a stop
(1) The load was over 85%
to the alarm level of [AL.
50.5 Thermal overload
error 2 during a stop].
Check it with the check method for [AL. 50.5].
E1.7 Thermal
overload error 3
during a stop
(1) The load was over 85%
to the alarm level of [AL.
51.2 Thermal overload
error 3 during
operation].
Check it with the check method for [AL. 51.2].
E1.8 Thermal
overload error 4
during a stop
(1) The load was over 85%
to the alarm level of [AL.
50.6 Thermal overload
error 4 during a stop].
Check it with the check method for [AL. 50.6].
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...