1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 51
Alarm No.: 3D
Name: Parameter setting error for driver communication
Alarm content
The control parameter setting value for driver communication is incorrect.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
3D.1 Parameter
combination
error for driver
communication
on slave
(1) The master transmit
data selection for driver
communication is not
set correctly.
Check the settings of
[Pr. PD16] and
[Pr. PD17] on the
master side.
The setting is
incorrect.
Set it correctly.
[B]
(slave)
3D.2 Parameter
combination
error for driver
communication
on master
Check it with the check method for [AL. 3D.1].
[B]
(master)
Alarm No.: 3E
Name: Operation mode error
Alarm content
The operation mode setting was changed.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
3E.1 Operation
mode error
(1) The MR-J4 servo
amplifier used in J3
compatibility mode was
connected to the other
SSCNET III/H controller.
Or an MR-J4 servo
amplifier which was
connected to SSCNET
III/H controller was
connected to another
SSCNET III controller.
Check if the
connection was
changed to like these.
The connection was
changed.
Initialize the servo
amplifier with the
built-in application
software "MR-
J4(W)-B mode
selection" of MR
Configurator2, and
then connect the
amplifier to the
controller.
[B]
[WB]
(2) The [Pr. PA01] setting
value was changed.
Check if [Pr. PA01]
was changed.
It was changed.
Set [Pr. PA01]
correctly.
3E.6 Operation
mode
switch error
(1) A method of positioning
data memorized in the
servo amplifier (point
table method/program
method) is different from
the actual positioning
mode (point table
method/program
method).
Check if the
positioning mode
(point table
method/program
method) was
changed.
Positioning mode:
[Pr. PA01] "_ _ _ x"
It was changed.
(with a purpose)
After changing the
positioning mode,
initialize the point
table method/
program method.
(Refer to section
7.2.8 [Pr. PT34] of
"MR-J4-_A_-RJ
Servo Amplifier
Instruction Manual
(Positioning Mode)")
[A]
It was changed by
mistake.
Set the positioning
mode back to the
correct setting.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...