1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 63
Alarm No.: 65
Name: Functional safety unit connection error
Alarm content
Communication or signal between a functional safety unit and servo amplifier failed.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
65.1 Functional
safety unit
communication
error 1
(1) The functional safety
unit came off.
Check the installation
of the functional
safety unit.
It is disconnected.
Turn off the control
circuit power supply
of the servo
amplifier, and then
connect the
functional safety unit.
[A]
[B]
[GF]
It is connected.
Check (2).
(2) The functional safety
unit is malfunctioning.
Replace the
functional safety unit,
and then check the
repeatability.
It is not repeatable.
Replace the
functional safety unit.
It is repeatable.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
It is repeatable.
Check (4).
(4) Something near the
device caused it.
Check the noise,
ambient temperature,
etc.
It has a failure.
Take
countermeasures
against its cause.
65.2 Functional
safety unit
communication
error 2
Check it with the check method for [AL. 65.1].
65.3 Functional
safety unit
communication
error 3
65.4 Functional
safety unit
communication
error 4
65.5 Functional
safety unit
communication
error 5
65.6 Functional
safety unit
communication
error 6
65.7 Functional
safety unit
communication
error 7
65.8 Functional
safety unit shut-
off signal error 1
65.9 Functional
safety unit shut-
off signal error 2
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...