Alarm No.
73
Power supply: Over regeneration
Over-regeneration detection level became over 100%. The regenerative resistor is overloaded. This alarm cannot be reset
for 15 min from the occurrence. Leave the drive system energized for more than 15 min, then turn the power ON to reset
the alarm.
Investigation details
Investigation results
Remedies
CV
1
Check the alarm occurrence state and
regenerative load displayed on the NC
Monitor screen while changing the
operation mode.
The regenerative load value increases
when the power is turned ON and the motor
is not rotated.
Check whether the state is affected by
power fluctuation, grounding or noise. If
there is no problem, replace the unit.
The regenerative load value increases each
time the motor decelerates, and the alarm
occurs.
A-CR:
Check the investigation item No. 2.
C1-CV:
Check the investigation item No. 4.
The regenerative load value increases each
time the motor decelerates, but the alarm
does not occur when the operation mode is
eased.
A-CR:
Check the investigation item No. 2.
C1-CV:
Ease the operation mode.
2
Check whether the parameter (regenerative
resistor type) of the drive unit controlling the
power supply unit is correct.
The setting is incorrect.
Correctly set. (Check the alarm No. "6D"
items.)
The setting is correct.
Check the investigation item No. 3.
3
Check the regenerative resistor's state.
[1] Is oil adhered?
[2] Measure the resistance value.
The regenerative resistor is abnormal.
Replace the regenerative resistor.
There is no problem.
Check the investigation item No. 4.
4
Check the alarm No. "75" items.
Alarm No.
75
Power supply: Overvoltage
L+ and L- bus voltage in main circuit exceeded the allowable value. As the voltage between L+ and L- is high immediately
after this alarm, another alarm may occur if this alarm is reset in a short time. Wait more than 5 min before resetting so that
the voltage drops.
Investigation details
Investigation results
Remedies
CV
1
Check the repeatability.
The alarm occurs each time the motor
decelerates.
Check the investigation item No. 3.
The alarm occurs occasionally.
Check the investigation item No. 2.
2
Check the power supply's alarm history.
Auxiliary regeneration frequency over (E8)
occurs just before the over-voltage occurs.
Limit the occurrence of the excessive
instantaneous regeneration by not
decelerating multiple axes at the same time.
Others.
Check the investigation item No. 3.
3
Check the power capacity.
The power capacity is insufficient.
Increase the power capacity.
The specified power capacity is secured.
Check the investigation item No. 4.
4
Measure the voltage across wires.
[1] Is the voltage 170V or more even when
the motor is accelerating?
The voltage drops to 170V or less
occasionally.
Increase the power capacity.
The difference of the voltage across wires is
10V or more.
Improve the power phase balance.
The difference of the voltage across wires is
less than 10V.
Check the investigation item No. 5.
5
Measure the power voltage with a
synchroscope, and check whether there is
any distortion.
[1] Are there any other devices causing the
power distortion?
The power voltage is distorted.
Improve the source of the distortion.
Install an AC reactor.
The power voltage waveform is not
abnormal.
Check the investigation item No. 6.
6
Check if there is any abnormality in the
unit's ambient environment.
(Ex. Noise, grounding, etc.)
Take remedies according to the causes of the abnormality in the ambient environment.
Alarm No.
76
Power supply: External emergency stop setting error
The rotary switch setting of external emergency stop is not correct, or a wrong external emergency stop signal is input.
Investigation details
Investigation results
Remedies
CV
1
Check the rotary switch setting.
When using external emergency stop,
rotary switch is not set to "4".
Set the rotary switch to "4".
2
Check if there is any abnormality in the
unit's ambient environment.
No abnormality is found in particular.
Replace the drive unit.
The grounding is incomplete.
Take remedies according to the causes of
the abnormality.
Additionally ground and review.
Содержание C70
Страница 1: ......
Страница 3: ......
Страница 9: ......
Страница 11: ......
Страница 13: ......
Страница 18: ...1 1 Outline ...
Страница 21: ...1 Outline MITSUBISHI CNC 4 ...
Страница 22: ...5 2 GOT Initial Setup ...
Страница 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Страница 74: ...57 3 PLC CPU Initial Setup ...
Страница 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Страница 92: ...75 4 CNC CPU Initial Setup ...
Страница 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Страница 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Страница 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Страница 116: ...99 6 Setting Machine Parameters ...
Страница 130: ...113 7 Setting the Position Detection System ...
Страница 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Страница 154: ...137 8 Deceleration Check ...
Страница 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Страница 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Страница 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Страница 170: ...153 10 Data Backup and Restoration ...
Страница 184: ...167 Appendix 1 Explanation of Parameters ...
Страница 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Страница 436: ...419 Appendix 2 Explanation of Alarms ...
Страница 608: ...591 Appendix 3 Display on 7 segment LED ...
Страница 624: ......
Страница 628: ......