Image Optimization
5-65
z
Rotate, zoom in/out and shift the 3D images, and reset the images to original
status by clicking [Reset].
z
Set 4D image view direction by clicking [Direction].
z
3D image editing (You can enter image cutting mode by clicking [Edit].).
z
Set the parameters to render 3D image.
z
Set the brightness, contrast and colorize map and so on for 3D image.
z
Section image viewing.
z
Image rotation (including auto rotation).
z
Save a single frame image, save the on-screen image.
z
Save cine and export AVI cine.
z
Review 3D images.
4D Cine Review
Press <Freeze> key on the control panel to enter cine review status.
Cine review parameters are described as follows:
Parameter
Description
Skip to First
Skip to the first frame of image.
Skip to Last
Skip to the last frame of image.
Set First Frame
To set the current frame as the start frame for a cine to be saved.
Method: review to a certain frame, and click [Set First Frame].
Set End Frame
To set the current frame as the end frame for a cine to be saved.
Method: review to a certain frame, and click [Set End Frame].
Auto Play
Activate auto play, and set the cine review speed.
Tips: when system is frozen, or when open a 4D cine file, rolling the trackball left/right
controls the cine frame backward/forward, while rolling the trackball up/down (a range
more than 45°) makes the 3D image move forward/backward around Z-axis. Press <Set>
or click soft menu item, the system returns to image viewing status.
5.11.5.6 4D Image Saving
In the 3D viewing mode, press the use-defined key for single image saving (Save
Image to hard drive) to save the current image to the patient information management
system in the set format and image size.
Save clip: in 3D viewing mode, press the user-defined key for cine saving key (Save
Clip (Retrospective) to hard drive) to save CIN-format clip to the hard drive.
Save as AVI: in auto rotation mode (freeze mode), click [Save AVI to USB] to save the
auto rotation images to the USB disk.
5.11.6 Static 3D
Static 3D provides single frame image acquisition of 3D images. Make sure to perform
static 3D imaging with an appropriate static 3D-compatible probe—4D probe. Only if the
current probe is an effective one, can the system enters static 3D imaging mode. During
the scanning, the probe performs the scanning automatically.
5.11.6.1 Basic Procedures for Static 3D Imaging
To perform static 3D imaging:
1. Select the appropriate static 3D-compatible probe and connect it to the ultrasound
system (the leftmost port). Make sure there is sufficient gel on the probe for scanning.
Содержание DC-T6
Страница 1: ...DC T6 Diagnostic Ultrasound System Operator s Manual Basic Volume...
Страница 2: ......
Страница 10: ......
Страница 16: ......
Страница 28: ......
Страница 37: ...System Overview 2 9 2 6 Introduction of Each Unit...
Страница 178: ......
Страница 182: ......
Страница 236: ......
Страница 240: ...13 4 Probes and Biopsy No Probe Model Type Illustration 19 CW2s Pencil probe...
Страница 300: ......
Страница 314: ......
Страница 320: ......
Страница 326: ......
Страница 330: ...C 4 Barcode Reader...
Страница 337: ...Barcode Reader C 11...
Страница 342: ......
Страница 347: ...P N 046 001523 01 V1 0...