Cortex-M3 Processor (Reference Material)
UG0331 User Guide Revision 15.0
56
number of branch instructions in code. The table also shows the relationship between condition code
suffixes and the N, Z, C, and V flags.
The following example shows the use of a conditional instruction to find the absolute value of a number.
R0 = abs(R1).
Example 1
Absolute value
MOVS R0, R1 ; R0 = R1, setting flags
IT MI ; skipping next instruction if value 0 or positive
RSBMI R0, R0, #0 ; If negative, R0 = -R0
The following example shows the use of conditional instructions to update the value of R4 if the signed
values R0 is greater than R1 and R2 is greater than R3.
Example 2
Compare and update value
CMP R0, R1 ; Compare R0 and R1, setting flags
ITT GT ; Skip next two instructions unless GT condition holds
CMPGT R2, R3 ; If 'greater than', compare R2 and R3, setting flags
MOVGT R4, R5 ; If still 'greater than', do R4 = R5
Table 29 •
Condition Code Suffixes
Suffix
Flags
Meaning
EQ
Z = 1
Equal
NE
Z = 0
Not equal
CS or HS
C = 1
Higher or same, unsigned
CC or LO
C = 0
Lower, unsigned
MI
N = 1
Negative
PL
N = 0
Positive or zero
VS
V = 1
Overflow
VC
V = 0
No overflow
HI
C = 1 and Z = 0
Higher, unsigned
LS
C = 0 or Z = 1
Lower or same, unsigned
GE
N = V
Greater than or equal, signed
LT
N != V
Less than, signed
GT
Z = 0 and N = V
Greater than, signed
LE
Z = 1 and N != V
Less than or equal, signed
AL
Can have any value Always. This is the default when no suffix is specified.
Содержание SmartFusion2 MSS
Страница 1: ...UG0331 User Guide SmartFusion2 Microcontroller Subsystem ...
Страница 166: ...Cortex M3 Processor Reference Material UG0331 User Guide Revision 15 0 132 ...
Страница 200: ...Embedded NVM eNVM Controllers UG0331 User Guide Revision 15 0 166 Figure 87 System Builder Window ...
Страница 407: ...Universal Serial Bus OTG Controller UG0331 User Guide Revision 15 0 373 ...
Страница 806: ...Fabric Interface Controller UG0331 User Guide Revision 15 0 772 Figure 345 FIC Master AHB Lite Subsystem ...