Fabric Interface Controller
UG0331 User Guide Revision 15.0
768
24.7.1.1 Step 1: Configure the MSS FIC Sub-Block
As shown in the following figure, the FIC configurator (applies to both FIC_0 and FIC_1) is organized as
follows. In the left panel, the following can be configured:
•
The MSS to the FPGA fabric interface
•
Advanced AHB-Lite options
•
The FPGA fabric address regions (MSS master view) – available in FIC_0 configurator only
In the right panel, a dynamic picture displays the high level block diagram of the architecture chosen. The
picture changes when any option in the MSS To FPGA fabric interface group is configured.
Figure 338 •
FIC Configurator
24.7.1.1.1 MSS to the FPGA Fabric Interface
Interface Type:
Use this option to select between the AMBA APB (AHB to APB bridge) and AHB-Lite
(AHB to AHB bridge) FIC modes (as shown in the following figure).
Use Master Interface:
Use this option to expose the Master Bus Interface (BIF) port. When selected, the
port is automatically available on the MSS core.
Use Slave Interface:
Use this option to expose the Slave Bus Interface (BIF) port. When selected, the
port is automatically available on the MSS core.
Figure 339 •
MSS to FPGA Fabric Interface Core
24.7.1.1.2 Advanced AHBLite Options
Use Bypass Mode:
Use this option to enable the FIC Bypass mode. This option is only active when the
interface type is AHB-Lite (as shown in the following figure). The clock ratio between M3_CLK,
Содержание SmartFusion2 MSS
Страница 1: ...UG0331 User Guide SmartFusion2 Microcontroller Subsystem ...
Страница 166: ...Cortex M3 Processor Reference Material UG0331 User Guide Revision 15 0 132 ...
Страница 200: ...Embedded NVM eNVM Controllers UG0331 User Guide Revision 15 0 166 Figure 87 System Builder Window ...
Страница 407: ...Universal Serial Bus OTG Controller UG0331 User Guide Revision 15 0 373 ...
Страница 806: ...Fabric Interface Controller UG0331 User Guide Revision 15 0 772 Figure 345 FIC Master AHB Lite Subsystem ...