Mechanical Components
The main internal mechanical components of the instrument are:
•
The source housing, inside which are the ion tunnels.
The ion tunnels are sometimes referred to as the “RF lenses”.
•
The analyser housing, containing the two quadrupoles and the gas cell.
•
The detector, attached to the rear of the analyser housing.
•
Two 250 litre/second turbomolecular pumps, one pumping each of the above
housings.
•
The active inverted magnetron (Penning) gauge and the Pirani gauge, both
clamped to the underside of the analyser housing.
•
The air filter, held in the louvered cover at the left side of the front of the
instrument.
Instrument Description
Page 32
Quattro Ultima
User's Guide
Analyser
Housing
Detector
Source
Housing
Air Filter
(behind cover)
Source
Turbomolecular
Pump
Active Inverted
Magnetron
(Penning) Gauge
Pirani
Gauge