© 2010 Magnum Energy, Inc.
72
6.0 Troubleshooting
6.2 Performing an Inverter Reset
Press and hold the Power ON/OFF button (see Figure 6-1) for approximately
fi
fteen (15) seconds until the Charging/Inverting Status LED comes on and
fl
ashes rapidly. Once the rapid
fl
ashing has begun, release the Power ON/
OFF button. The Status LED will go off after the button is released.
After the inverter reset is completed, press the Power ON/OFF button to turn
the inverter ON.
Some older inverter models do not allow an inverter reset. If the inverter reset
fails you will need to power-down the inverter using the procedure below. In
either case, if an internal fault does not clear the inverter will require repair
at an authorized service facility.
Info:
The Power ON/OFF button is a small momentary type
switch which operates by lightly pressing and releasing.
Info:
All adjustable inverter/charger settings in the router
(except Setup
01B Contrast
,
01C Backlight
, and
03 Gen Control
- which revert back to default) are saved in non-volatile memory
and are preserved until changed - even if an inverter reset is
performed or if all power to the router or inverter is removed.
1. Press and hold the Power
ON/OFF pushbutton for 15
seconds.
2. Watch the Charging/
Inverting Status LED, after
approximately 15 seconds it
should come on and flash
rapidly to indicate the inverter
has reset. The Status LED will
go off after the pushbutton is
released .
Figure 6-1, Performing an Inverter Reset
6.3 Powering Down the Inverter
To power-down the inverter:
Remove all AC power (utility or generator power) to the inverter.
Open all the inverter DC disconnects (or disconnect the positive bat-
tery cable to the inverter).
Ensure all inverters and the router are disconnected from all AC and
DC power (the router display will be blank).
After the inverters have been disconnected from all power for 30
seconds, reconnect the inverter DC disconnects (or reconnect the
positive battery cable) and resume operation.
Info:
If DC disconnects are not used, there may be a momen-
tary spark when the positive battery cable is connected to the
inverter’s terminal. This is normal and indicates that the inverter’s
internal capacitors are being charged.
1.
2.
3.
4.