![Magnum Energy ME-RTR Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/magnum-energy/me-rtr/me-rtr_owners-manual_694518052.webp)
47
© 2010 Magnum Energy, Inc.
4.0 Menu Map
SETUP Button’s Charger Menu Map starts on the top of the next page
Range: OFF, 5 to 50 Watts
Ranges: 9-12.2
(12V)
, 18-24.4
(24V)
, 36-48.8
(48V)
Ranges: 12:00AM to 11:59PM
.....
….......
continued….
SETUP
1 Router
2 Inverter
3 Charger
ALL Select Setup
02A Search Watts
OFF
ALL View INV Setup
Set Search Watts
OFF
ALL edit INV Setup
Set Search Watts
50 Watts
ALL EDIT INV Setup
02B Low Bat Cutout
9.0 Volts
ALL View INV Setup
Set Low Bat Cutout
9.0 Volts
ALL edit INV Setup
Set Low Bat Cutout
12.2 Volts
ALL EDIT INV Setup
02C AC In - Time
6:00am – 6:00pm
ALL View INV Setup
Set Connect Time
6:00am
ALL edit INV Setup
S
S
S
Range: 9-16
(12V)
, 18-32
(24v)
, 36-64
(48v)
02D AC In VDC
11.0V - 14.1V
ALL View INV Setup
Set Connect Volts
11.0 Volts
ALL edit INV Setup
Set Disconnect Volts
14.1 Volts
ALL edit INV Setup
S
Range: OFF, 30% - 90% (10% increments)
02E Parallel
Threshold OFF
ALL View INV Setup
Set Parallel
Threshold OFF
ALL edit INV Setup
Set Parallel
Threshold 90%
ALL EDIT INV Setup
S
…......
Set Search Watts
5 Watts
ALL EDIT INV Setup
Set Disconnect Time
6:00pm
ALL edit INV Setup
S
S
S
Default: 5 Watts
Defaults: 10 VDC
(12V)
, 20 VDC
(24V)
, 40 VDC
(48V)
Default: 6:00 am – 6:00 pm
Default: 11.0 – 14.1 VDC
(12v)
, 22-28.2
(24v)
,
44-56.4
(48v)
Default: 60%
Figure 4-5, SETUP Button Menu Map - Inverter (Page 5 of 9)
4.0 Menu Map: ME-RTR Router Control (continued)