3.0 Setup
3.2.2 CTRL (Control) Button
The CTRL button contains the menus for
01 AC In Control
,
02
CHG Control
,
and
03
Gen Control
(an AGS must be connected in order for the Gen Control
menu to display). The CTRL button gives you quick control of the main functions
of the inverter/charger without having to access the SETUP menus in order
to change the operation of the inverter/charger or the generator. Once the
settings have been programmed in the SETUP menus, the features can then
be enabled using the CTRL button.
Example:
The SETUP menu’s
02C AC In - Time
setting is used to set what
time of day (e.g., 12AM to 8AM) you want the inverter to connect to the
incoming AC. Once this time is set, use the CTRL button to access the
AC In Control
menu item and select
Time Connect
. When
Time Connect
is selected, the inverter/charger will only connect to AC when the time
is between 12AM and 8AM.
01 AC In Control
Auto Connect
View Control
CTRL
Button
Press to
edit setting
Press
CTRL
Rotate to
desired
selection:
01 AC In Control
Auto Connect
View Control
Top line shows menu
Bottom line shows view
01 AC In Control
Auto Connect
View Control
02 CHG Control
Multi -Stage
View Control
03 Gen Control
OFF
View Control
Figure 3-3, CTRL (Control) Button