© 2010 Magnum Energy, Inc.
50
4.0 Menu Map
4.0 Menu Map: ME-RTR Router Control (continued)
TECH Menu Map continues on the top of the next page
04A Gen Run VDC
13.0V – 14.4V
P1A View AGS Setup
05A Charge Eff
Auto
P1A View BMK Setup
INV Batt Sensor Temp
1 25C 2 --- 3 ---
4 --- 5 --- 6 ---
ALL Tech 01A
INV FETs Temp
1 28C 2 --- 3 ---
4 --- 5 --- 6 ---
ALL Tech 01C
INV Transformer Temp
1 28C 2 ---
3 ---
4 ---
5 ---
6 ---
ALL Tech 01B
Firmware Versions
1 INV 2 ---
3 ---
4 ---
5 ---
6 ---
Router: 2.1 Tech 02
Fault History
Press Select
to view
Tech 04
H1 High Volts AC
Off
22.0Vdc 0Idc
P1 0 5:35aTech 04
H1 High Volts AC
BTS 25C Tfmer 45C
FETs 44C
P1 0 5:35aTech 04
H9 AC Overload
Inverting
27.0Vdc -200Idc
P1 7 4:30pTech 04
Displays: Fault History Number (H1 to H9), Fault
Mode, INV/CHG Status, Volts DC, Amps DC, Day
Since Fault, Time Fault Occurred, and BTS Temp,
Transformer Temp, and Transistor (FETs) Temp
when fault occurred.
Refer to the
ME-AGS-N Owner’s Manual
(PN: 64-0039) for detailed information on this menu.
Refer to the
ME-BMK/ME- BMK-NS Owner’s Manual
(PN: 64-0013) for detailed information on this menu.
TECH
S
S
H9 AC Overload
BTS 25C Tfmer 85C
FETs 80C
P1 7 4:30aTech 04
.......
Firmware Versions
1 AGS 2 --- 3 ---
4 --- 5 --- 6 ---
Acc Tech 03
06A Remote Monitor
System
P2 View Remote Setup
S
Remote Control
MS4024 on port 1
Inverting
P4 Remote Home
This display is used to assign the port that the
remote will monitor when multiple inverters
are connected. Example to left: remote is
connected to Port 4 and will monitor inverter
connected to Port 1.
S
Note: The accessory SETUP menus below (AGS, BMK, ARC remote)
are accessed via the System Home screen and PORT button. Refer
to procedures on pages 36-37 for these three menu items .
Figure 4-8, SETUP (Accs)/TECH Menu Map (Page 8 of 9)