1.0 Overview
1.0 Overview
The ME-RTR, or “router” hereafter, has many of the same features as the
ME-ARC50 advanced remote with the added functionality required to paral-
lel Magnum MS-PAE inverter/chargers. The router is designed to easily and
quickly connect the MS-PAE series inverter/charger in parallel without the
need to program each inverter. The router will accommodate up to four MS-
PAE inverter/chargers in parallel plus accessories.
The ME-RTR is equipped with the following features:
LED Indicators
-
The at-a-glance LEDs provide the inverter/charger,
router, communication ports, and auxiliary relay statuses in a
straightforward way.
LCD Display
-
The LCD display is a 20 x 4 line (80 characters total)
alphanumeric display used for setting up the inverter/charger operation,
as well as viewing current status or fault messages.
ON/OFF Pushbuttons (x2)
-
Allows all the inverters or chargers to be
quickly enabled or disabled.
Info:
The router’s ON/OFF INVERTER and ON/OFF CHARGER
buttons function normally when a ME-ARC is connected
through a router in a parallel system.
PORT Button
-
This button scrolls through the six communication and
accessory ports and displays information.
CTRL Button
-
This button is used to select inverter, charger, and AGS
functions previously set up using the SETUP button.
METER Button
-
This button is used to access the ‘read only’ meters for
DC, AC, AGS, and BMK.
SETUP Button
-
This button is used to access the setup menus for the
inverter, charger, AGS, and BMK. The SETUP button may be password
protected to keep unauthorized users from accessing the SETUP
menus.
•
•
•
•
•
•
•
Inverting
25.6 VDC 20 Amps
System Home
PORT, CTRL, METER, SETUP,
TECH Buttons
Rotary
SELECT Knob
LCD Display
LED
ON/OFF
LED Indicators
Figure 1-1, Front Panel Features