Maintenance
Repair
MagneMover LITE User Manual
55
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
7.
Locate the replacement magnet array and place flat on the work surface away from the
vehicle.
8.
Place the previously removed shim(s) on the top surface of the replacement magnet
array. Slide the shims around the array posts but do not allow the ends to extend
beyond the outer edges of the array.
NOTE:
If the shims are removed, or additional shims added, the length of the screws
must be adjusted appropriately.
9.
Place the mounting holes on the vehicle over the array posts. Realign the shims if nec-
essary to ensure they line up with the vehicle.
10.
Secure the array to the vehicle using the two M4 x 12 mm screws removed in
and Loctite 243. Tighten each screw to 1.5 N-m [13 in-lb].
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the vehicle.
11.
Replace Precision Rail Vehicles
.
12.
Restart the Path.
13.
Dispose of the removed magnet array appropriately.