Installation
Transport System Installation
MagneMover LITE User Manual
17
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
3.
Slide the bracket down until it makes positive contact with the floor and tighten the
M8 screws to 26 N-m [230 in-lb] using a 6 mm Hex bit.
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the transport
system.
4.
Secure the bracket to the floor.
Tie-down Using Feet
The feet on the MagneMover LITE should be secured to the facility floor to prevent system
movement by drilling a hole through each of the indicated locations on the feet that will be
secured and installing an appropriate fastener.
Figure 5-7: Foot Tie-down
Tie-down Location
(2X)