Specifications and Site Requirements
Electrical Specifications
46
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
AC Power Cable
The MM LITE Power Supply is supplied with a power cable. Contact MagneMotion for
replacement cables. The AC power cable plugs directly into the power supply.
NOTE:
There is no need for the user to construct the power cables as all cabling is supplied
with the transport system.
Table 4-12: MM LITE Power Supply DC Power Pinouts
Individual Terminals
V+ Propulsion
Black
V+ Logic
White
V- Return
*
*
MMI recommends tying V- Return to RTN.
Red
RTN
Green
Table 4-13: MM LITE Power Supply DC Enable
DE-9, Female
Pin
Signal
1
DC-OK
*
*
DC-OK signal is 0 - 1V when the PS is off and be-
tween 3.3 - 5.6V when the PS is on. The sinking cur-
rent is 10mA max.
2
RTN
3
+Bus Enable
†
†
Can be shorted via a transistor to enable propulsion
power. The sinking current is 20mA max.
4
-Bus Enable
5
—
6
—
7
—
8
—
9
—
7
8
2
3