Installation
Facilities Connections
62
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
power disconnect. Then, connect the DC power cable to the power connector
on each NC-12 Node Controller as shown in
2.
Connect power to each Node Controller LITE:
•
When supplying Power over Ethernet to the NC LITE, ensure the Ethernet
connection goes to a PoE enabled switch then plug the switch power supply
into the power distribution from the facility’s main power disconnect. Then,
connect the cable from the switch power supply to the switch.
•
When supplying power directly to each NC LITE, plug the NC LITE power
supply into the power distribution from the facility’s main power disconnect.
Then, connect the cable from the NC LITE power supply to the NC LITE as
shown in
3.
Connect an AC power cable from the power distribution on the facility’s main power
disconnect to the power connector on the MM LITE Power Supply as shown in
E-Stop Circuit
The MagneMover LITE transport system can use Digital I/O, provided through an NC-12
Node Controller, for monitoring and control of local options such as an E-Stop. The optional
E-Stop circuit is the responsibility of the user and requires a user-supplied E-Stop button and
+3 - 24 VDC power supply for the Digital Input. Refer to
Digital I/O Equivalent Circuits. Refer to
for the E-Stop circuit. Refer to
the
MagneMover
®
LITE Configurator User’s Manual
for information on configuring an
E-Stop.
Interlock Circuit
The MagneMover LITE transport system can use Digital I/O, provided through an NC-12
Node Controller, for monitoring and control of local options such as a Interlocks. The optional
Interlock circuit is the responsibility of the user and requires a user-su3 - 24 VDC
power supply for the Digital Input. Refer to
for the Digital I/O
Equivalent Circuits. Refer to
for the Interlock circuit. Refer to the
MagneMover
®
LITE Configurator User’s Manual
for information on configuring an Inter-
lock.
CAUTION
High Voltage Hazard
The E-Stop is not the same as an EMO (Emergency Off),
which removes power to the MagneMover LITE transport
system.