Installation
Transport System Installation
34
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Installing Motor Communications Cables
for the communication connection loca-
tions on the motors and switches and
nection locations on the Node Controllers in the MagneMover LITE transport system. Refer
to
for simplified diagrams of the wiring and to
detailed example. Note that the connections for a diverge switch are different than the connec-
tion shown in
for a merge switch.
NOTE:
Both ends of a Path do not need to connect to the same Node Controller. However,
all connections to the motors at the ends of all Paths meeting in a Node must be
made to the same Node Controller. Refer to the
MagneMover
®
LITE Configurator
User’s Manual
for more information about Nodes and Paths.
Figure 5-20: Communication Cable Connections
1.
Connect an external communications cable from an RS-422 connector on the Node
Controller to the upstream end of the first motor in a Path (as defined in the transport
system layout drawing) and route the cable in the cable chase (refer to
).
•
For an NC-12 Node Controller, connect to any RS-422 port, finger tighten
only.
Upstream
Upstream
Downstream
Upstream
Downstream Connection
External Communications Cable
(typical)
Downstream
Connection
Connection
Node Controller
1 meter Motor
1/4 meter
Motor
Downstream
Upstream
Connection
Connection
(NC-12 Shown)
Connection
Internal Communications Cable
(typical)