214685
170
Revision A
Figure 7.30: Float Indicator Box
17. Adjust cable take-up bracket (B) (if necessary) until
pointer (A) on float indicator is on 0.
7.1.3
Case IH 5088/6088/7088 Combines
Calibrating the Auto Header Height Control (Case IH 5088/6088/7088)
For best performance of the auto header height control (AHHC) system, perform ground calibration with center-link
set to
D
. When calibration is complete, adjust the center-link back to desired header angle. For instructions, refer to
the header operator
’
s manual.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
NOTE:
If header float is set too light, it can prevent calibration of AHHC. You may need to set the float heavier for
calibration procedure so header doesn
’
t separate from the float module.
Figure 7.31: Right Console
1.
Ensure center-link is set to
D
.
2.
Set the float. Refer to operator
’
s manual for
instructions. Position fore-aft in mid span.
3.
Start the combine engine, but do
NOT
engage
separator or feeder house.
4.
Locate HEADER CONTROL switch (A) on the right
console, and set to HT (this is AHHC mode).
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header Published June 2018...
Страница 12: ......
Страница 42: ......
Страница 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Страница 72: ......
Страница 116: ......
Страница 153: ...214685 141 Revision A Figure 6 66 Deck Support Locations Left Shown Right Opposite PERFORMING PREDELIVERY CHECKS...
Страница 166: ......
Страница 336: ......
Страница 350: ......
Страница 353: ......