214685
303
Revision A
Figure 7.329: New Holland Combine Display
9.
Select GRAPH (A). The exact voltage (B) is displayed
at the top of the screen.
10. Raise and lower the header to see the full range of
voltage readings.
11. If the sensor voltage is not within the low and high
limits, or if the range between the low and high limits is
insufficient, adjust the voltage limits. Refer to
Voltage Limits: One-Sensor System, page 162
Setting up Auto Header Height Control (New Holland CR Series)
For best performance of the auto header height control (AHHC), perform these procedures with the center-link set
to
D
. When setup and calibration are complete, adjust the center-link back to desired header angle.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
NOTE:
This section applies only to 2015 and later CR models (6.80, 6.90, 7.90, 8.90, 9.90, and 10.90). For other pre-2015
New Holland combine models, refer to
7.1.15 New Holland Combines (CR/CX Series
Figure 7.330: New Holland Combine Display
1.
Ensure center-link is set to
D
.
2.
Select TOOLBOX (A) on the main screen. The
TOOLBOX screen displays.
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header Published June 2018...
Страница 12: ......
Страница 42: ......
Страница 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Страница 72: ......
Страница 116: ......
Страница 153: ...214685 141 Revision A Figure 6 66 Deck Support Locations Left Shown Right Opposite PERFORMING PREDELIVERY CHECKS...
Страница 166: ......
Страница 336: ......
Страница 350: ......
Страница 353: ......