214685
83
Revision A
Figure 5.51: Switch Harness Routing
12. Secure switch harness (A) at multicoupler with a cable
tie. Leave 100 cm (40 in.) extending past location (B).
5.3.3
Attaching Header to John Deere Combine
WARNING
To avoid bodily injury or death from unexpected start-up of machine, always stop engine and remove key
from ignition before leaving operator
’
s seat for any reason.
Figure 5.52: Combine and Float Module
1.
Push handle (A) on the combine multicoupler
receptacle towards the feeder house to retract the
pins (B) at the bottom corners of the feeder house.
Clean the receptacle.
CAUTION
Never start or move the machine until you are sure all
bystanders have cleared the area.
2.
Start the engine and slowly drive the combine up to the
header until the feeder house saddle (C) is directly
under the float module top cross member (D).
3.
Raise the feeder house slightly to lift the header
ensuring the feeder house saddle is properly engaged
in the float module frame.
4.
Stop the engine and remove the key from the ignition.
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header Published June 2018...
Страница 12: ......
Страница 42: ......
Страница 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Страница 72: ......
Страница 116: ......
Страница 153: ...214685 141 Revision A Figure 6 66 Deck Support Locations Left Shown Right Opposite PERFORMING PREDELIVERY CHECKS...
Страница 166: ......
Страница 336: ......
Страница 350: ......
Страница 353: ......