214685
174
Revision A
Figure 7.39: Case IH Combine Display
7.
Locate the HHC HEIGHT SENSITIVITY field (A), and
set as follows:
•
If using a two-sensor system:
Set HHC HEIGHT
SENSITIVITY to 250.
•
If using a single-sensor system:
Set HHC
HEIGHT SENSITIVITY to 180.
NOTE:
If hunting occurs during operation, decrease this setting
by 20 points at a time until hunting no longer occurs.
8.
Set HHC TILT SENSITIVITY (B) to 150. Increase or
decrease as desired.
Figure 7.40: Case IH Combine Display
9.
From the REEL DRIVE TYPE menu (A), select
•
4 if you are using a standard 19-tooth drive sprocket
•
5 if you are using an optional high-torque 14-tooth
drive sprocket
•
6 if you are using an optional high-torque 10-tooth
drive sprocket
Figure 7.41: Case IH Combine Display
10. From the REEL HEIGHT SENSOR menu (A),
select YES.