214685
32
Revision A
Figure 4.3: Top Gasket
3.
Remove top gasket (A) for use in the next step.
NOTE:
There are two gaskets
—
one on each side of the filler
strainer flange.
Figure 4.4: Filler Cap Neck
4.
Place gasket (A) (removed from the top of the filler
strainer) onto the filler cap neck (B) and align holes.
5.
Install #10-32 screws (if supplied with cap, otherwise
use existing screws) into filler cap neck (B) and push
screws through gasket (A).
6.
Apply hydraulic pipe controlled strength pipe thread
sealant (Loctite
®
565 or equivalent) to screws.
Figure 4.5: Screw Hole Locations
7.
Place filler cap neck (A) (complete with screws) over
opening and ensure the machine screws are aligned
with the threaded holes.
8.
Carefully thread in the machine screws using a cross
pattern (as shown) in order to prevent cross threading
of tapped holes.
9.
Repeat pattern to gradually tighten screws to 3.5 Nm
(31 lbf·in).