214685
263
Revision A
Figure 7.235: John Deere Combine Display
7.
Select the AHHC SENSING option.
8.
Press the icon that resembles an arrow in a box (A).
The AHHC SENSING menu appears and five screens
of information are displayed.
Figure 7.236: John Deere Combine Display
9.
Press icon (A) until it reads Page 5 near the top of the
screen and the following sensor readings appear:
•
LEFT HEADER HEIGHT
•
CENTER HEADER HEIGHT
•
RIGHT HEADER HEIGHT
A reading is displayed for both left and right sensors.
On the MacDon header, there may be one sensor
located in the float indicator box (standard) or two
sensors located at the back of the float module side
frame (optional).
10. Ensure header float is unlocked.
11. Start the combine and fully lower feeder house to the ground.
NOTE:
You may need to hold the HEADER DOWN switch for a few seconds to ensure the feeder house is fully
lowered.
12. Check the sensor reading on the monitor.
13. If the sensor voltage is not within the low and high limits or if the range between the low and high limits is
insufficient, refer to
Содержание FlexDraper FD1 Series
Страница 2: ...FD1 Series FlexDraper Header Published June 2018...
Страница 12: ......
Страница 42: ......
Страница 45: ...214685 33 Revision A Figure 4 6 Filler Cap 10 Install filler cap A SETTING UP FLOAT MODULE...
Страница 72: ......
Страница 116: ......
Страница 153: ...214685 141 Revision A Figure 6 66 Deck Support Locations Left Shown Right Opposite PERFORMING PREDELIVERY CHECKS...
Страница 166: ......
Страница 336: ......
Страница 350: ......
Страница 353: ......