40
Function list
5.2 Function group 1
LED
display
Address
for
communi-
cation
Parameter
name
Min/
Max
range
Description
Factory
defaults
Adj.
during
run
Page
F 0
A200
[Jump code]
0 - 99 Sets the parameter code number to jump. 1
O
F 1
A201
[Forward/
Reverse run
disable]
0 - 2
0 Fwd and rev run enable
0
X
1 Forward run disable
2 Reverse run disable
F 2
A202
[Accel pattern]
0 - 1
0 Linear
0
X
F 3
A203
[Decel pattern]
1 S-curve
F 4
A204
[Stop mode
select]
0 - 3
0 Decelerate to stop
0
X
1 DC brake to stop
2 Free run to stop
3 Power Braking stop
F 5
A205
[Power On
Start select]
0 - 1
This parameter is activated when drv is set
to 1 or 2 (Run/Stop via Control terminal).
Motor starts acceleration after AC power is
applied while FX or RX terminal is ON.
0
O
F 6
A206
[Run Time
Delay]
0-
6000.
0
[sec]
Run after the time set
0
X
F 8
1)
A208
[DC Brake
start
frequency]
0.1 -
60
[Hz]
This parameter sets DC brake start
frequency.
It cannot be set below F23 - [Start
frequency].
5.00
X
F 9
1)
A209
[DC Brake
wait time]
0 - 60
[sec]
When DC brake frequency is reached, the
inverter holds the output for the setting
time before starting DC brake.
0.1
X
F10
1)
A20A
[DC Brake
voltage]
0 -
200
[%]
This parameter sets the amount of DC
voltage applied to a motor.
It is set in percent of H33
– [Motor rated
current].
50
X
F11
1)
A20B
[DC Brake
time]
0 - 60
[sec]
This parameter sets the time taken to
apply DC current to a motor while motor is
at a stop.
1.0
X
F12
A20C
[DC Brake
start voltage]
0 -
200
[%]
This parameter sets the amount of DC
voltage before a motor starts to run.
It is set in percent of H33
– [Motor rated
current].
50
X
F13
A20D
[DC Brake
start time]
0 - 60
[sec]
DC voltage is applied to the motor for DC
Brake start time before motor accelerates.
0
X
F14
A20E
[Time for
magnetizing a
motor]
0 - 60
[sec]
This parameter applies the current to a
motor for the set time before motor
accelerates during Sensorless vector
control.
0.1
X
F20
A214
[Jog
frequency]
0 -
400
[Hz]
This parameter sets the frequency for Jog
operation.
It cannot be set above F21
– [Max
frequency].
10.00
O
1)
Only displayed when F 4 is set to 1 (DC brake to stop).
Содержание SV-iG5H Series
Страница 1: ...Thank you for purchasing LS Variable Frequency Drives ...
Страница 14: ......
Страница 20: ...6 Installation Wiring 2 2 Dimensions SV004iG5H 2 SV008iG5H 2 SV004iG5H 4 SV008iG5H 4 SV015iG5H 2 SV015iG5H 4 ...
Страница 23: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O ...
Страница 24: ...10 Installation Wiring ...
Страница 51: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern ...
Страница 140: ...Advanced functions 126 The following pattern is shown when the H26 Number of auto restart try is set to 2 ...
Страница 174: ...Protective functions 160 ...
Страница 220: ...206 DECLARATION OF CONFIRMITY ...
Страница 224: ...210 ...
Страница 226: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 ...