Advanced functions
102
►
When F65 is 1: It is increased as many as step frequency set as F66 at the rising edge
of multi-function input set as UP and when up-down is defined, it saves frequency at the
falling edge. It is decreased as many as step frequency set as F66 at the falling edge of
rising edge of multi-function input set as DOWN and when up-down is defined, it saves
frequency as the falling edge. In this case, while multi-function input set as UP or
DOWN is defined, if stop command is inputted, previous falling edge value is saved and
if multi-function input is not defined, present frequency is not saved. The accel/decel
time is same with when stetted as
“0”.
►
When F65 is 2: It is increased as many as step frequency set as F66 at the rising edge
of multi-function input set as UP and if it is activated for 3 second, it operates like
something set as
“0”. It is decreased as many as step frequency set as F66 at the rising
edge of multi-function input set as DOWN and if it is activated for 3 second, it operates
like something set as
“0” and the accel/decel time is same with when stetted as “0”.
Because of UP or DOWN, when the input is entered again before it is increased as many as 1
step frequency, the input is ignored and the saved frequency is also frequency of the
inactivated moment
Содержание SV-iG5H Series
Страница 1: ...Thank you for purchasing LS Variable Frequency Drives ...
Страница 14: ......
Страница 20: ...6 Installation Wiring 2 2 Dimensions SV004iG5H 2 SV008iG5H 2 SV004iG5H 4 SV008iG5H 4 SV015iG5H 2 SV015iG5H 4 ...
Страница 23: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O ...
Страница 24: ...10 Installation Wiring ...
Страница 51: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern ...
Страница 140: ...Advanced functions 126 The following pattern is shown when the H26 Number of auto restart try is set to 2 ...
Страница 174: ...Protective functions 160 ...
Страница 220: ...206 DECLARATION OF CONFIRMITY ...
Страница 224: ...210 ...
Страница 226: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 ...