Specifications
199
Sp
ecif
ica
tio
ns
Operation
13.1.4
Operation mode
Keypad/ Terminal/ Communication option/ Remote keypad
selectable
Frequency setting
Analog: 0 - 10[V], -10 - 10[V], 0 - 20[mA]
Digital: Keypad
Operation features
PID, Up-down, 3-wire
Input
Multi-function
terminal
P1 - P4
NPN / PNP selectable
FWD/REV RUN, Emergency stop, Fault reset,
Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step
Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor
select, Frequency UP/Down, 3-wire operation, External trip A, B,
PID-Inverter (v/f) operation bypass, Option-inverter (v/f) operation
bypass, 2nd Source, Analog Hold, Accel/Decel stop,
Up/Down Save Freq, Jog FX/RX, Fire mode, motor alternation
Output
Multi-function relay1
Fault output and inverter
status output
Less than AC 250V 1A
Less than DC 30V 1A
Multi-function relay2
Less than AC250V 1A,
Less than DC 30V 1A
Analog output
0 - 10 Vdc (less than10mA): Output Freq, Output Current, Output
Voltage, DC link selectable
Protective function
13.1.5
Trip
Over Voltage, Under Voltage, Over Current, Over Current 2,
Ground Fault current detection, Inverter Overheat, Motor
Overheat, Output Phase Open, Overload Protection,
Communication Error, Loss of Speed Command, Hardware
Fault, Fan trip, Brake error, Overpressure, Broken Belt,
Underload Trip, Pipe broken.
Alarm
Stall prevention, overload
Momentary Power Loss
1)
Below 15 msec: Continuous operation (should be within rated
input voltage, rated output power.)
Above 15 msec: Auto restart enable
1) Single Phase products: Continuous operation (should be within rated input voltage, rated output
power)
Содержание SV-iG5H Series
Страница 1: ...Thank you for purchasing LS Variable Frequency Drives ...
Страница 14: ......
Страница 20: ...6 Installation Wiring 2 2 Dimensions SV004iG5H 2 SV008iG5H 2 SV004iG5H 4 SV008iG5H 4 SV015iG5H 2 SV015iG5H 4 ...
Страница 23: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O ...
Страница 24: ...10 Installation Wiring ...
Страница 51: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern ...
Страница 140: ...Advanced functions 126 The following pattern is shown when the H26 Number of auto restart try is set to 2 ...
Страница 174: ...Protective functions 160 ...
Страница 220: ...206 DECLARATION OF CONFIRMITY ...
Страница 224: ...210 ...
Страница 226: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 ...