DRAW operation example
If draw operation is set to 30Hz, F70=3(V1: -10V -10V), F71=10.0% selected, (I3-I15 =
plant shipment) Frequency that gets changed by DRAW operation is 27Hz(V1=-10V) -
33Hz(V1=10V)
When operating DRAW, set command frequency to FRQ/FRQ2 and set the rest of it from
F70(DRAW mode select). For example, if FRQ=2(V1) and F70=1(V1), it does not operate.