Advanced functions
138
8.31 Parameter read/write
Group
Code
Parameter Name
Setting
Range
Default
Unit
Function
group 2
H91
[Parameter read]
1
0 - 1
0
H92
[Parameter write]
1
0 - 1
0
Used to read/write Inverter Parameters using remote keypad.
Take caution when Parameter write (H92) is executed. By doing this, parameters in inverter are
cleared and parameters in remote keypad are copied to inverter.
Parameter read
8.31.1
Step
Note
Keypad display
1
Move to H91 code.
H91
2
Press Enter (
) key once.
0
3
Press Up (
) key once.
Rd
4
Press Enter (
) key twice.
rd
5
H91 is displayed when Parameter read is finished.
H91
Parameter write
8.31.2
Step
Note
Keypad display
1
Move to H92 code.
H92
2
Press Enter (
) key once.
0
3
Press Up (
) key once.
Wr
4
Press Enter (
) key twice.
Wr
5
H91 is displayed when Parameter read is finished.
H92
Содержание SV-iG5H Series
Страница 1: ...Thank you for purchasing LS Variable Frequency Drives ...
Страница 14: ......
Страница 20: ...6 Installation Wiring 2 2 Dimensions SV004iG5H 2 SV008iG5H 2 SV004iG5H 4 SV008iG5H 4 SV015iG5H 2 SV015iG5H 4 ...
Страница 23: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O ...
Страница 24: ...10 Installation Wiring ...
Страница 51: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern ...
Страница 140: ...Advanced functions 126 The following pattern is shown when the H26 Number of auto restart try is set to 2 ...
Страница 174: ...Protective functions 160 ...
Страница 220: ...206 DECLARATION OF CONFIRMITY ...
Страница 224: ...210 ...
Страница 226: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 ...