Advanced functions
98
8.2 Jog operation
Terminal jog operation
8.2.1
Group
Code
Parameter Name
Setting
Range
Default
Unit
Function
group 1
F20
[Jog frequency]
-
0 - 400
10.00
Hz
I/O group
I21
[Multi-function input terminal
P4 define]
4
0 - 30
3
Set the desired jog frequency in F20.
Select a terminal from P1
– P4 to use for this setting.
If P4 is set for Jog operation, set I20 to 4 {Jog}.
Jog frequency can be set within the range of F21 - [Max frequency] and F23
– [Start
frequency].
►
Jog operation overrides all other operations except Dwell operation. Therefore, if Jog
frequency command is entered in the middle of Multi-Step, Up-Down or 3-wire
operation, operation is executed at Jog frequency.
►
The above diagram is an example when Multi-function input is set to NPN mode.
►
Terminal jog operation
Содержание SV-iG5H Series
Страница 1: ...Thank you for purchasing LS Variable Frequency Drives ...
Страница 14: ......
Страница 20: ...6 Installation Wiring 2 2 Dimensions SV004iG5H 2 SV008iG5H 2 SV004iG5H 4 SV008iG5H 4 SV015iG5H 2 SV015iG5H 4 ...
Страница 23: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O ...
Страница 24: ...10 Installation Wiring ...
Страница 51: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern ...
Страница 140: ...Advanced functions 126 The following pattern is shown when the H26 Number of auto restart try is set to 2 ...
Страница 174: ...Protective functions 160 ...
Страница 220: ...206 DECLARATION OF CONFIRMITY ...
Страница 224: ...210 ...
Страница 226: ...212 Revision History No Date Edition Changes 1 2018 05 08 First Release First Release 2 3 4 5 6 7 8 9 ...