IES-0883 User Manual
Page 12
Front Panel Display
Power & Port Status LEDs
The LEDs are located on the front panel, displaying status for each respective
port. Please refer to the following table for more details.
Te
rmin
al
B
lo
ck
PW1
+
12 – 32VDC
–
Power Ground
PW2
+
12 – 32VDC
–
Power Ground
Earth Ground
Relay Output
1A @ 24VDC
Relay Alarm warning signal disable for following:
3.
The relay contact closes if Power1 and Power2 are both failed but Power3 on
4.
The relay contact closes if Power3 is failed but Power1 and Power2 are both on
•
There are three power inputs can be used. Redundant power function is supported
PW3
is DC Jack type with 12VDC input
Содержание IES-0883
Страница 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Страница 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Страница 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Страница 152: ...IES 0883 User Manual Page 151 ...