IES-0883 User Manual
Page 121
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable coldStart
command to enable cold start trap for
SNMP.
Use the
no snmp-server trap-type enable coldStart
command to disable cold start trap
for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable coldStart
4.
Example:
The following example enables cold start trap for SNMP:
switch_a(config)#snmp-server trap-type enable coldStart
switch_a(config)#
Warm Start Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable warmStart
command to enable warm start trap for
SNMP.
Use the
no snmp-server trap-type enable warmStart
command to disable warm start
trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable warmStart
4.
Example:
The following example enables warm start trap for SNMP:
switch_a(config)#snmp-server trap-type enable warmStart
switch_a(config)#
Link Down Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
Содержание IES-0883
Страница 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Страница 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Страница 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Страница 152: ...IES 0883 User Manual Page 151 ...