SNMP v3
Add User:
1.
Add User: Click “Add User” button. The “SNMP V3 Setting” window appears.
2.
SNMP Version: Click “SNMP Version” drop-down menu from “SNMP Version” drop-down
list to choose “SNMPv3 No-Auth”, “SNMPv3 Auth-MD5”, “SNMPv3 Auth-SHA”, “SNMPv3
Priv Auth-MD5”, or “SNMPv3 Priv Auth-SHA”.
Ÿ
SNMPv3 No-Auth: Add a user using SNMP v3 without authentication.
Ÿ
SNMPv3 Auth-MD5: Add a user using SNMP v3 with authentication. Click in the “Auth.
Password” textbox and specify an authentication password.
Ÿ
SNMPv3 Auth-SHA: Add a user using SNMP v3 with authentication. Click in the “Auth.
Password” textbox and specify an authentication password.
Ÿ
SNMPv3 Priv Auth-MD5: Add a user using SNMP v3 with authentication and privacy.
Click in the “Auth. Password” textbox and specify an authentication password. Click in
the “Privacy PassPhrase” textbox and specify a privacy pass phrase.
Ÿ
SNMPv3 Priv Auth-SHA: Add a user using SNMP v3 with authentication and privacy.
Click in the “Auth. Password” textbox and specify an authentication password. Click in
the “Privacy PassPhrase” textbox and specify a privacy pass phrase.
3.
User Name: Click in the “User Name” textbox and specify a user name for user using
SNMP v3.
4.
Access Mode: Click “Access Mode” drop-down menu from “Access Mode” drop-down list
to choose “Read Only” or “Read/Write”.
Ÿ
Read Only: Add a user using SNMP v3 with read-only access mode.
Ÿ
Read/Write: Add an user using SNMP v3 with read-write access mode
5.
Sumit: Click “Sumit” button when you finished SNMP V3 Setting.
Содержание IES-0883
Страница 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Страница 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Страница 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Страница 152: ...IES 0883 User Manual Page 151 ...