– Simple Network Management Protocol (SNMP) version 3.0; SNMP Trap version 1.0
– Common Information Model (CIM)
– Web browser
For more information about the IMM2, see “Using the integrated management module” on page
57, Appendix A “Integrated management module II (IMM2) error messages” on page 329, and
the
Integrated Management Module II User's Guide
at http://publib.boulder.ibm.com/infocenter/
systemx/documentation/topic/ com.lenovo.sysx.imm2.doc/ printable_doc.html.
•
Dynamic System Analysis
DSA Preboot diagnostic program is stored in the integrated USB memory on the server. DSA Preboot
collects and analyzes system information to aid in diagnosing server problems, as well as offering a
rich set of diagnostic tests of the major components of the server. DSA Preboot collects the following
information about the server:
– Drive health information
– IMM2 configuration information
– IMM2 environmental information
– Event logs for ServeRAID controllers and service processors
– Installed hardware, including PCI and USB information
– LCD system information display panel (if available) status
– Microprocessor, input/output hub, and UEFI error logs
– Network interfaces and settings
– Option card driver and firmware information
– RAID controller configuration
– Service processor (integrated management module) status and configuration
– System configuration
– Vital product data, firmware, and UEFI configuration
DSA Preboot also provides diagnostics for the following system components (when they are installed):
1. Emulex network adapter
2. IMM I2C bus
3. LCD system information display panel (available on some models)
4. Memory modules
5. Microprocessors
6. Optical devices (CD or DVD)
7. SAS or SATA drives
8. LSI Controller
9. Broadcom network adapter
10. FusionIO storage
11. Intel GPU
12. Nvidia GPU
See “Running the DSA Preboot diagnostic programs” on page 82 for more information on running the
DSA Preboot program on the server.
•
Troubleshooting by symptom
These tables list problem symptoms and actions to correct the problems. See “Troubleshooting by
symptom” on page 83 for more information.
74
Lenovo System x3650 M5 Installation and Service Guide
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1329: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1317 ...
Страница 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1339: ......
Страница 1340: ......