• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
• Go to the support website at http://www.lenovo.com/support to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Symptom
Action
• Riser-card assembly 1 (See “Removing a riser-card assembly” on page 186
and “Replacing a riser-card assembly” on page 188).
• Optional adapter (if one is present) installed in riser-card assembly 1 (See
“Removing an adapter” on page 192 and “Replacing an adapter” on page
196).
• Optional adapter (if one is present) in PCIe slot 5
• Optional adapter (if one is present) in PCIe slot 4
• Raid Card in Raid slot
5. (Trained technician only) remove all components
6. (Trained technician only) replace the system board (see “Removing the system
board” on page 292 and “Replacing the system board” on page 294).
7. Reinstall the Microprocessor 1; then, restarting the server. If the Pwr rail G error
has been recorded in the system event log again, the Processor that you just
reinstalled is defective. Replace the defective Processor.
• (Trained technician only) Microprocessor 1 (See “Removing a microprocessor
and heat sink” on page 276 and “Replacing a microprocessor and heat sink”
on page 281).
The Pwr rail H error has been
recorded in the system event
log.
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail H error has been recorded in
the system event log:
• Hard disk drives at backplane assembly 3
• Hard disk drive backplane assembly 3
• PCIe Solid state drives
• PCIe Solid state drive backplane assembly
3. Restart the server. If the Pwr rail H error has been recorded in the system event
log again, (trained technician only) replace the system board (see “Removing the
system board” on page 292 and “Replacing the system board” on page 294).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr rail H error has been recorded in the system event
log again, the component that you just reinstalled is defective. Replace the
defective component.
• Hard disk drive backplane assembly 3
• Hard disk drives at backplane assembly 3
• PCIe Solid state drive backplane assembly
• PCIe Solid state drives
98
Lenovo System x3650 M5 Installation and Service Guide
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...